Below is only a summary of product data. Please download the product datasheet for complete details.
| Generic Type | Cycloaliphatic Amine Epoxy | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Common Usage | Tightly cross-linked epoxy with excellent corrosion and chemical resistance. Principally used for immersion service, including fuel storage, chemcial containment and wastewater treatment. | ||||||||||||
| Colors | 5002 Beige (prime coat) and 5001 Gray (finish coat) | ||||||||||||
| Finish | Semi-gloss | ||||||||||||
| Primers | Steel: Self-priming Concrete: Self-priming or Series 214, 218 CMU: Series 218 |
||||||||||||
| Volume Solids | 82.0 ± 2.0% (mixed) † | ||||||||||||
| Recommended DFT | 1. For JP-4, JP-5, JP-8, Aviation Gas and Jet A-1: 4.0 to 6.0 mils (100 to 150 microns) per coat (minimum of two coats). 2. Most Other Applications: 8.0 to 12.0 mils (205 to 305 microns) per coat (minimum of two coats). Contact your Tnemec representative for specific recommendations. |
||||||||||||
| Curing Time |
Curing time varies with surface temperature, air movement, humidity and film thickness. • Maximum recoat time is 72 hours. If more than 72 hours have elapsed between coats, the coated surface must be scarified before topcoating. |
||||||||||||
| Volatile Organic Compounds | EPA Method 24 Unthinned: 0.36 lbs/gallon (45 grams/litre) Thinned 10%: 1.94 lbs/gallon (232 grams/litre) † |
||||||||||||
| HAPS | Unthinned: 1.59 lbs/gal solids Thinned 10%: 2.49 lbs/gal solids |
||||||||||||
| Theoretical Coverage | 1,315 mil sq ft/gal (32.3 m²/L at 25 microns). See APPLICATION for coverage rates. † | ||||||||||||
| Number Of Components | Two: Part A and Part B |
The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

Tneme-Liner was applied to the Tampa Bay Water Treatment Plant.