Below is only a summary of product data. Please download the product datasheet for complete details.
| Generic Type | Modified Polyamine Epoxy |
|---|---|
| Common Usage | High solids coating which offers high-build edge protection and excellent corrosion resistance. For use on the interior and exterior of steel or concrete tanks, reservoirs, pipes, valves, pumps and equipment in potable water service as well as other steel and concrete substrates. |
| Colors | ANSI/NSF Std. 61 colors: 1211 Red, 1255 Beige, 33GR Gray and WH03 Off-White. Note: Other colors may be available for non-potable water applications. Contact your Tnemec representative. Minimum order requirements may apply. Note: Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur. |
| Primers | Self-priming, 1, 27, 37H, L69, L69F, N69, N69F, 90E-92, 90-97, 91-H2O, 94-H2O, 135, L140, L140F, N140, N140F, 394, 530 |
| Topcoats | Exterior: Series 73, 180, 1074, 1075, 1080. Refer to COLORS on applicable topcoat data sheets for additional information. Note: The following maximum recoat time applies when using Series 73, 180, 1074, 1075 or 1080: thirty (30) days. If this time limit is exceeded, Series 141 must be uniformly scarified prior to topcoating. |
| Volume Solids | 82% ± 2.0% (mixed) † |
| Recommended DFT | 4.0 to 18.0 mils (100 to 455 microns) in one coat. Note: Thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative. Maximum dry film thickness for NSF exposure is 18.0 mils. |
| Volatile Organic Compounds | Unthinned: 1.30 lbs/gallon (156 grams/litre) Thinned 5%: 1.57 lbs/gallon (188 grams/litre) Thinned 10%: 1.81 lbs/gallon (217 grams/litre) † |
| HAPS | Unthinned: 1.3 lbs/gal solids Thinned 5%: 1.6 lbs/gal solids Thinned 10%: 1.9 lbs/gal solids |
| Theoretical Coverage | 1,315 mil sq ft/gal (32.2 m²/L at 25 microns). See APPLICATION for coverage rates. † |
| Number Of Components | Two: Part A and Part B |
The products listed below are not exact equivalents. They are only products that you may consider as alternatives in a general sense. Substrate type, condition, temperatures, surface preparation, primer/topcoat selection and intended use are just a few factors that will affect product selection. Please contact your local Tnemec Coatings Consultant for product recommendations.

Series 141 Pota-Pox 80 applied at the Texas A&M Chiller Plant.